SL150 Installation and Setup Guide
16–4
To Delete a Serial
Number
To delete an existing serial number, enter 0 in the loop number
field. The serial number will change to 0's.
10 INPUT S/N:
L
A000-0000 0
If 0 was entered in error, simply re-enter the loop number or
press [#], and the serial number will return to the display.
Zn ZT RC In: L
10 03 10 RF:
1s
If the serial number transmitted matches the serial
number entered, the keypad will beep 3 times and a summary
display will appear, showing that zone's programming. Note that
an “s” indicates that a transmitter’s serial number has been
enrolled.
Press [
] to accept the zone information and display the
PROGRAM ALPHA? prompt.
PROGRAM ALPHA?
0 = NO 1 = YES 0
If you want to program descriptors for zones now, enter 1 (Yes) and
refer to Section 19: Alpha Descriptor Programming for
available descriptors.
ENTER ZN NUM.
(00 = QUIT) 11
If
0
(No) was entered above, the system will return you to the
ENTER ZN
NUM.
prompt for the next zone.
When all zones have been programmed, enter
00
to quit
.
When you have finished programming all zones, test each zone using the system’s TEST mode.
Do not use the Transmitter ID Sniffer Mode for checking wireless transmitting devices
, as
it will only check for transmission of one zone on a particular transmitter, NOT the zones
assigned to each additional loop.
NOTE
:
Following the successful enrollment of each wireless device, remove ONE of the
serial number labels from the device and affix it in the appropriate column on the
ENROLLED TRANSMITTERS worksheet in the Programming Form; then enter the other
information (zone number, zone type, loop number, etc.) relevant to that device.
58 Expert Programming Mode Procedures
Enter the program mode and follow the step-by-step instructions that follow.
Note: Before proceeding, you must program field
22 (RF System) and field
25 (Wired Zone
Expansion) as required.
SET TO CONFIRM?
0 = NO 1 = YES 0
Press
58. This display will appear upon entry into this mode.
The default is 0 (No).
If 1 (Yes) is entered, you will be prompted to confirm each
transmitter after entering the serial and loop numbers (at the
“XMIT TO CONFIRM” prompt later).
Zn
ZT RC IN: L
01 09
10 HW: 1
A summary screen will appear, showing zone 1’s current
programming or default values.