Security Link SL150 Guida alla Risoluzione dei Problemi

Navigare online o scaricare Guida alla Risoluzione dei Problemi per Sistemi di controllo di accesso Security Link SL150. Security Link SL150 Troubleshooting guide [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
6/
6HF XULW\6\VWHP
,QVWDOODWLRQDQG6HWXS*XLGH
1
2
3
654
897
0
*
#
OFF
AWAY STAY
MAX TEST BYPASS
INSTANT
CODE CHIME
READY
ARMED
READY
1
2
3
654
897
0
*
#
OFF
AWAY STAY
MAX TEST BYPASS
INSTANT
CODE CHIME
READY
ARMED
READY
N7526–8V1 3/00
Vedere la pagina 0
1 2 3 4 5 6 ... 143 144

Sommario

Pagina 1 - 6HF XULW\6\VWHP

6/6HF XULW\6\VWHP,QVWDOODWLRQDQG6HWXS*XLGH1236548970*#OFFAWAY STAYMAX TEST BYPASSINSTANTCODE CHIMEREADYARMEDREADY1236548970*#OFFAWAY STAYMAX TE

Pagina 2

SL150 Installation and Setup Guide1–2Security Codes• One Installer code for entire system (user 1)•One Master code for entire system (user 2)• 12 Seco

Pagina 3

SL150 Installation and Setup Guide18–2Pager 1 Reporting - Zone List 06Pager 1 reporting is an option that must be set up using zone list 06, and enter

Pagina 4 - Table of Contents

19–1SECTION 19Alpha Descriptor Programming••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Alpha Descriptor Programming♦Zone De

Pagina 5

SL150 Installation and Setup Guide19–2Program Alpha?0=No, 1=Yes 002. Press ✱82.The Program Alpha? prompt will appear.Custom Words ?0=No, 1=Yes 003. Pr

Pagina 6

Section 19 - Alpha Descriptor Programming19–3✳ ZN 01 BACKDOOR Flashing Cursor if “6” ispressed (system isready for next word). 9. Press 6 to accep

Pagina 7 - List of Figures

SL150 Installation and Setup Guide19–45. Press 8 to save the custom word(s) and return to the “CUSTOM WORD ?” display.Repeat Steps 2–5 for other custo

Pagina 8

Section 19 - Alpha Descriptor Programming19–5ALPHA VOCABULARY LIST(For Entering Zone Descriptors)000(Word Space)– A –•001 AIR• 002 ALARM004 ALLEY005

Pagina 9 - Introduction

SL150 Installation and Setup Guide19–6

Pagina 10

20–1SECTION 20Macros (SpeedKey)••••••••••••••••••••••••••••••••••••••••••••••••••♦About Macros (SpeedKey)♦ Macro Key Programming••••••••••••••••••••••

Pagina 11

SL150 Installation and Setup Guide20–2SPEED LEARN MODE 60219F#71F2FYou can enter up to 16 keystrokes to program a macro. There areno wordspaces betwee

Pagina 12 - FINAL POWER

21–1SECTION 21Remote Programming andControl (Downloading)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Remote Programming♦Eq

Pagina 13 - Installing the Control

Section 1 - Introduction1–3Optional Phone Module• Supports the Ademco 4285/4286 VIP Module (refer to Section 8 for furtherinformation).• Provides acce

Pagina 14

SL150 Installation and Setup Guide21–2– Hayes Smartmodem Optima 2400– Hayes Optima 2400 Fax96– Hayes Smartmodem 1200 External Modem– Hayes Smartmodem

Pagina 15 - RCVR BRD

22–1SECTION 22System Communication••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Panel Communication with Central Station♦ Report C

Pagina 16 - ON CONTROL

SL150 Installation and Setup Guide22–23+1 and 4+1 Standard FormatsComprise a 3- (or 4-) digit subscriber number and a single digitreport code (e.g. Al

Pagina 17 - Wiring the AC Transformer

Section 22 - System Communication22–3The Ademco Contact ID reporting format comprises a 10-digit subscriber account number, 1-digit event qualifier (“

Pagina 18 - Earth Ground Connections

SL150 Installation and Setup Guide22–4

Pagina 19 - Installing Remote Keypads

23–1SECTION 23System Operation••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Security Codes♦Keypad Functions♦Relay/Powerline Carrie

Pagina 20 - Mounting the Keypads

SL150 Installation and Setup Guide23–2Notes:• All Master and Secondary User codes permit access to the system for arming, disarming, etc.• The Install

Pagina 21 - AUX. DATA

Section 23 - System Operation23–3Wired keypads contain the following dedicated quick arming keys :No security code is required to arm the system using

Pagina 22

SL150 Installation and Setup Guide23–4Exit Error Alarm Displays (if programmed)•A display of CANCELED ALARM or CA and a zone indication will appear if

Pagina 23 - Basic Hardwired Zones 1–8

Section 23 - System Operation23–5Telephone Line FailureA display of CHECK 94 (on fixed-word keypads) or TELCO FAULT (on alpha keypads)indicates that a

Pagina 24

SL150 Installation and Setup Guide1–4Dynamic Signaling FeatureThis control features Dynamic Signaling Delay and Dynamic Signaling Prioritymessage repo

Pagina 25

SL150 Installation and Setup Guide23–6

Pagina 26

24–1SECTION 24Testing the System••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Test Procedure•••••••••••••••••••••••••••••••••••••

Pagina 27 - Remote Keyswitch (Zone 7)

SL150 Installation and Setup Guide24–2a. TRANSMITTER SNIFFER MODEMake sure the system is disarmed before trying to enter this mode.Press [Installer co

Pagina 28

25–1SECTION 25Troubleshooting Guide•••••••••••••••••••••••••••••••••••••••••••••••••• (including Wireless)SYMPTOM POSSIBLE CAUSE REMEDY1. Transmitter

Pagina 29

SL150 Installation and Setup Guide25–2 (including Wireless - cont'd)SYMPTOMPOSSIBLE CAUSE REMEDY5b. If no response at all from thistransmitter, t

Pagina 30

Section 25 – Troubleshooting Guide25–3SYMPTOM POSSIBLE CAUSE REMEDY1. Detector alarms, noapparent reason.1a. Dust, dirt in sensing chamber.1b. Imprope

Pagina 31

SL150 Installation and Setup Guide25–4

Pagina 32

26–1SECTION 26Specifications & Accessories••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Specifications♦Accessories••••••••••••

Pagina 33 - Wired Zone Expansion

SL150 Installation and Setup Guide26–2SL6150 REMOTE KEYPADError!Bookmark not defined.1. Physical: 6-1/2” W x 5-7/8” H x 1-5/16” D (150mm x 124mm x 33m

Pagina 34

Section 26 Specifications & Accessories26–34204 RELAY MODULE1. Physical: 6-1/2” W x 4-1/4” H x 1-1/4” D (169mm x 108mm x 32mm)2. Electrical:Volta

Pagina 35

2–1SECTION 2Installing the Control••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Mounting the Cabinet♦Installing the Lock♦Mounting

Pagina 36

SL150 Installation and Setup Guide26–4Ademco 747Self-contained 12-volt siren (driver built-in) for indoor wallmount. 747F available for flush mountin

Pagina 37 - Wireless Expansion

A–1APPENDIX A5800 RF System Wireless Transmitters••••••••••••••••••••••••••••••••••••••••••••••••••5800 Series Transmitter Input Loop IdentificationAl

Pagina 38 - 1 2 3 4 5

SL150 Installation and Setup GuideA–2

Pagina 39 - Jam Detection and Reporting

B–1APPENDIX BRegulatory Agency Statements••••••••••••••••••••••••••••••••••••••••••••••••••UL NOTICE: This is a “Grade A” residential system.FEDERAL C

Pagina 40

SL150 Installation and Setup GuideB–2Regulatory Agency Statements (Continued)FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENTThis equipment c

Pagina 41

C–1APPENDIX CWarnings and Limitations••••••••••••••••••••••••••••••••••••••••••••••••••WARNING!THE LIMITATIONS OF THIS ALARM SYSTEMWhile this System i

Pagina 42 - Appendix A

SL150 Installation and Setup GuideC–2Limitations of This Alarm System (Continued)•Alarm warning devices such as sirens, bells or horns may not alert p

Pagina 43

Index–1Index••••••••••••••••••••••••••••••••••••••••••••••••••1011BE12M...26–31321...

Pagina 44

IndexIndex-2AC Restore Report Code...15–9AC Transformer... 2–5Access

Pagina 45

IndexIndex-3Deleting a Serial Number ...16–7deleting the zone list...18–1Descr

Pagina 46

SL150 Installation and Setup Guide2–2Before installing the cabinet's contents, remove the metal cabinet knockouts required for wiringentry. Do no

Pagina 47 - Powerline Carrier Devices

IndexIndex-4Memory-of-Alarm...4–3model 112...

Pagina 48 - Programming Relay Outputs

IndexIndex-5Sescoa/Radionics Select...15–6Setting Program Fields to Default Values...15–13Silent Burglary ...

Pagina 50 - Verification (AAV) Unit

AUX. POWEROUTPUT10.5-13.8VDC600mA MAX.(500mA MAX.FOR ULINSTALLATIONS)INTERRUPTSFOR 4-WIREFIRE ALARMRESET. ALL CIRCUITSARE POWERLIMITED.NOTE:KEYPAD(S)

Pagina 51 - VIP MODULE

¬19'lN7526-8V1 3/00LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions,subsidiaries

Pagina 52

Section 2 - Installing the Control2–35. Swing the base of the board into the mounting clips and secure it to the cabinet with theaccompanying screws (

Pagina 53 - External Sounders

SL150 Installation and Setup Guide2–4Standard Phone Line ConnectionsThe wiring connections shown here are not applicable if the4285/4286 VIP Module is

Pagina 54 - Testing the Sounder

Section 2 - Installing the Control2–5Wiring the AC Transformer1321 TransformerWire the 1321 Transformer to terminals 1 and 2 on the control board. See

Pagina 55 - Long Range Radio

SL150 Installation and Setup Guide2–6Installing the Backup BatteryIf necessary, refer to Section 12: Final Power-Up for information regarding battery

Pagina 56 - Dynamic Signaling Feature

3–1SECTION 3Installing Remote Keypads••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Keypads That May Be Used♦Wiring to the Keypads♦

Pagina 58 - 4285 or 4286

SL150 Installation and Setup Guide3–2The length of all wire runs must not exceed 1500 feet (457m) when unshielded quad conductorcable is used (750 fee

Pagina 59 - Final Power-Up

Section 3 – Installing Remote Keypads3–3Make connections directly to the screw terminals as shown in Figure 7. Make no connection to thekeypad blue wi

Pagina 60 - Battery Tests

SL150 Installation and Setup Guide3–4

Pagina 61 - Mechanics of Programming

4–1SECTION 4Basic Hardwired Zones 1–8••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Installing the Hardwired Zones♦ Keyswitch Inst

Pagina 62

SL150 Installation and Setup Guide4–22. If an EOL resistor is presently connected across zone 1 terminals, remove it. The EOLresistor must be connecte

Pagina 63 - Exiting the Programming Mode

Section 4 – Basic Hardwired Zones4–3Remove 2000 ohm EOL resistor if connected across the selected zone terminals. You mustconnect the EOL resistor acr

Pagina 64

SL150 Installation and Setup Guide4–4Wiring 2-Wire Latching Glass Break Detectors On Zone 8Use zone 8 for connection of compatible 2-wire latching-typ

Pagina 65

Section 4 – Basic Hardwired Zones4–5Remote Keyswitch (Zone 7)An optional remote 4146 keyswitch for remote arming and disarming of the system can beins

Pagina 66

SL150 Installation and Setup Guide4–61234567894146 KEYSWITCH4142TR CABLEVIOLETGRAYYELLOWREDGREENBROWNBLUEBLACKWHITE9-PINCONNECTORON CONTROL PANEL(READ

Pagina 67

Section 4 – Basic Hardwired Zones4–7Programming For The Remote Keyswitch1. Using a 2-line Alpha keypad, enter the programming mode by entering:Install

Pagina 68

iiiRECOMMENDATIONS FOR PROPER PROTECTIONThe Following Recommendations for the location of Fire and Burglary DetectionDevices Help Provide Proper Cover

Pagina 69 - Data Field Descriptions

SL150 Installation and Setup Guide4–8Typical summary displayZn ZT RC In RT07 77 3C HW: 1A summary display will appear, showing the data forzone 0

Pagina 70

Section 4 – Basic Hardwired Zones4–93. Fault and then restore every contact or sensor on each zone individually to ensure that itis being monitored by

Pagina 71

SL150 Installation and Setup Guide4–10

Pagina 72

5–1SECTION 5Wired Zone Expansion••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Installing Zone Expansion Units♦Connections and Setu

Pagina 73

SL150 Installation and Setup Guide5–24219GRNBLK(–) GROUNDRED(+) 12VDCYEL4321ZONESABCDFGHTAMPER JUMPERPOSITION 229IN CABINET (NOT TAMPERED)4229 REMOTE(

Pagina 74 - OUTPUT TO LONG RANGE RADIO

Section 5 –Wired Zone Expansion5–3Programming Wired Expansion ZonesEach zone must be programmed into the system using either the ✱56 Zone Programmingm

Pagina 75

SL150 Installation and Setup Guide5–4

Pagina 76

6–1SECTION 6Wireless Expansion (5800 System)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ About Wireless Expansion♦ Installing th

Pagina 77

SL150 Installation and Setup Guide6–2Installing the 5881/5882 ReceiverRF System Installation AdvisoriesFollow the guidelines below when installing the

Pagina 78

Section 6 - Wireless Expansion6–3Installing the 5800TM ModuleInstallation of this module is necessary only if you are using one or more 5827BD wireles

Pagina 79

Table of ContentsivTable of ContentsList of Figures ...

Pagina 80

SL150 Installation and Setup Guide6–4For button transmitters (RF “keys”), such as the 5801, 5804, and 5804BD, you must assign aunique zone number to e

Pagina 81 - Allows

Section 6 - Wireless Expansion6–5Some transmitters (e.g., 5802, 5802CP) contain long-life but non-replaceable batteries, andno battery installation is

Pagina 82

SL150 Installation and Setup Guide6–65800 Series Transmitters TableAlso refer to Appendix A for transmitter input loops/button locations.Model Descrip

Pagina 83 - Zone Programming

Section 6 - Wireless Expansion6–7Installing 5800 Series TransmittersThe following should be performed after the transmitters have been enrolled into t

Pagina 84

SL150 Installation and Setup Guide6–8

Pagina 85

7–1SECTION 7Relay Outputs & Powerline Carrier Devices••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Relays and Powerline

Pagina 86 -

SL150 Installation and Setup Guide7–23. Connect the desired field wiring to the unit's relay contact terminals.Supervision4204 and 4229 modules a

Pagina 87

Section 7 - Relay Outputs & Powerline Carrier Devices7–34204 ADDRESS SETTINGSSWITCHNUMBER("—" means "OFF")011 2 3 4 5 6 7 8 9

Pagina 88 - To Remove a Zone

SL150 Installation and Setup Guide7–4Wiring ConnectionsTo wire the Powerline Carrier Device to the control panel, perform the following steps:1. Splic

Pagina 89

8–1SECTION 84285 & 4286 VIP Module••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About the 4285 & 4286 VIP Module♦Installin

Pagina 90

Table of ContentsvSECTION 8 4285 & 4286 VIP Module ...

Pagina 91 - Section 16 -Zone Programming

SL150 Installation and Setup Guide8–2If you are also using an Audio Alarm Verification (AAV) unit, refer to Section 11: Audio AlarmVerification (AAV)

Pagina 92

Section 8 - 4285/4286 VIP Phone Module8–34285/4286 VIP MODULE WIRING NOTES:• Wire the phone module exactly as shown, using a direct-connect cord and R

Pagina 93 - Output Device Programming

SL150 Installation and Setup Guide8–4Programming the 4285/4286 VIP ModuleYou must program the system for use with the 4285 or 4286 VIP Module. This in

Pagina 94

9–1SECTION 9External Sounders••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Compatible Sounders♦NFPA Requirements♦Sounder Connectio

Pagina 95

SL150 Installation and Setup Guide9–2Sounder Connections and PowerThe SL150 provides a 12VDC output, which can power external alarm sounders (bells or

Pagina 96

10–1SECTION 10Long Range Radio••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Long Range Radio♦Wiring Connections♦Dynamic Sign

Pagina 97

SL150 Installation and Setup Guide10–2Dynamic Signaling FeatureThis control panel features Dynamic Signaling Delay and Dynamic Signaling Prioritymessa

Pagina 98

11–1SECTION 11Audio Alarm Verification (AAV) Unit••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Audio Alarm Verification♦Wiri

Pagina 99 - Zone Lists

SL150 Installation and Setup Guide11–2CONTROL/DIALER HEADERNOTE:REFER TO AAV MODULE INSTRUCTIONS FOR CONNECTIONS TO AUDIO SPEAKERS AND MICROPHONE.••••

Pagina 100

12–1SECTION 12Final Power-Up••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Earth Ground Connections♦AC Power-Up♦Connecting the Back

Pagina 101 - Alpha Descriptor Programming

Table of ContentsviSECTION 18 Zone Lists...

Pagina 102

SL150 Installation and Setup Guide12–2Example: If total auxiliary device current drain is 450mA, add 100mA for the control panel,for a total of 550mA

Pagina 103 - Adding Custom Words

13–1SECTION 13Mechanics of Programming••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Programming♦Entering Program Mode♦Progra

Pagina 104

SL150 Installation and Setup Guide13–2Entering Program ModeYou may use one of the following methods:a) Press [✱] and [#] keys at the same time within

Pagina 105 - CHARACTER (ASCII) CHART

Section 13 - Mechanics Of Programming13–3Loading Factory DefaultsThe control panel is shipped from the factory loaded with its factory defaults. To re

Pagina 106

SL150 Installation and Setup Guide13–4

Pagina 107 - Macros (SpeedKey)

14–1SECTION 14Zone Response Type Definitions••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Zone Type Definitions•••••••••••••••••••

Pagina 108

SL150 Installation and Setup Guide14–2Type 04Interior FollowerThis zone type gives a delayed alarm (using the programmedentry/exit time) if the entry/

Pagina 109 - Control (Downloading)

Section 14 - Zone Response Type Definitions14–3Type 10Interior w/DelayThis zone type gives Entry Delay (using the programmed entrytime), if tripped wh

Pagina 110 - Initial Download

SL150 Installation and Setup Guide14–4

Pagina 111 - System Communication

15–1SECTION 15Data Field Descriptions••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦ Descriptions of System Data Fields••••••••••••

Pagina 112

viiList of FiguresFigure 1. Installing the Cabinet Lock...

Pagina 113

SL150 Installation and Setup Guide15–2✱25 WIRED ZONE EXPANSION 0 0 = no expander module connected1 = 4219 connected2 = 4229 connected 3 = 4204 conn

Pagina 114

Section 15 -Data Field Descriptions15–3✱30 KEYSWITCH ENABLE (ZONE 7) 0 0 = disable; 1 = enableA keyswitch can only be used on zone 7. See Section

Pagina 115 - System Operation

SL150 Installation and Setup Guide15–4✱38 CONFIRMATION OF ARMING DING 0 0 = no ding1 = confirmation ding after arming system2 = confirmation ding a

Pagina 116 - Keypad Functions

Section 15 -Data Field Descriptions15–5✱47 PHONE SYSTEM SELECT 3 If Central Station is NOT on a WATS line: 0 = Pulse dial, 1 = Tone dialIf Central

Pagina 117

SL150 Installation and Setup Guide15–6✱53 SESCOA/RADIONICS SELECT 0 0 = Radionics (0–9, B–F reporting)1 = SESCOA (0–9 only reporting)Select 0 for a

Pagina 118

Section 15 -Data Field Descriptions15–7TO PROGRAMSYSTEM STATUSAND RESTOREREPORT CODES(✱59 –✱76, & ✱89)Report codes can be programmed using the int

Pagina 119

SL150 Installation and Setup Guide15–8✱60 TROUBLE REPORT CODE (See box on previous page) 1 | 0 This will be sent if a zone goes into trouble.✱61

Pagina 120

Section 15 -Data Field Descriptions15–9✱72 BYPASS RESTORE REPORT CODE 0 | 0 See box on a previous page. This is sent when a zone that has been by

Pagina 121 - Testing the System

SL150 Installation and Setup Guide15–10✱84 PAGER REPORTS 0 0 0 = No reports sent Pgr 1 Pgr 21 = Open/close for all users3 = Open/close for

Pagina 122

Section 15 -Data Field Descriptions15–11✱87 PAGER #2 PHONE NO. | | | | | | | | | | | | | | | | | | | Enter up

Pagina 123 - Troubleshooting Guide

viiiConventions Used In This ManualBefore you begin using this manual, it is important that you understand the meaning of the followingsymbols:ULA UL

Pagina 124 - CAUSE REMEDY

SL150 Installation and Setup Guide15–12✱91 OPTION SELECTION 8 0 = not using AAV2 = Macros (speed key)4 = an Audio Alarm Verification (AAV) unit is c

Pagina 125 - CONTACTING TECHNICAL SUPPORT

Section 15 -Data Field Descriptions15–13✱95 RING DETECTION COUNT FOR DOWNLOADING 15 0–15 = number of rings before control picks up phone lineRefer

Pagina 126

SL150 Installation and Setup Guide15–14

Pagina 127 - In This Section

16–1SECTION 16Zone Programming(✱56/✱58 Menu Mode)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Zone Programming♦✱56 Zone Pro

Pagina 128

SL150 Installation and Setup Guide16–2 Zone Number10 Zone TypePerimeter 03Zone Type Zone Type (ZT): Enter the Zone Type response (or change it, ifnec

Pagina 129

Section 16 -Zone Programming16–310 INPUT S/N: L A022-4064 1Note: The [A] and [B] keysmay be used to move thecursor to the right (A) or left(

Pagina 130

SL150 Installation and Setup Guide16–4To Delete a SerialNumber →To delete an existing serial number, enter 0 in the loop numberfield. The serial numb

Pagina 131 - APPENDIX A

Section 16 -Zone Programming16–5Zn ZT RC IN: L10 – – – : –Zn ZT RC IN: L10 00 10 RF: 1*If HW (hardwired) or

Pagina 132

SL150 Installation and Setup Guide16–610 XMIT TO CONFIRMPRESS ✱ TO SKIPThe prompt to confirm appears. This prompt will only appearif the first prompt

Pagina 133 - Regulatory Agency Statements

Section 16 -Zone Programming16–7will not be deleted if the zone is temporarily disabled byanswering “No” to the previous prompt.If only the physical t

Pagina 134

1–1SECTION 1Introduction••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦General Description♦Features••••••••••••••••••••••••••••••••

Pagina 135 - Warnings and Limitations

SL150 Installation and Setup Guide16–8ENTER START ZONE00 = QUIT 36Example of zone ↑suggested by the system. This indicates that zones 36, 37, 38,

Pagina 136

Section 16 -Zone Programming16–9Wireless Key Predefined Default TemplatesYOU MUSTPROGRAMMETHIS BUTTONLOOP 3LOOP 1LOOP 2LOOP 4ENROLL AS "BR"

Pagina 137

SL150 Installation and Setup Guide16–10

Pagina 138

17–1SECTION 17Output Device Programming(✱80 and ✱81 Menu Mode)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦Programming Options De

Pagina 139

SL150 Installation and Setup Guide17–22. Zone List (ZL) is a group of zones to which the event applies in order toactivate a particular device. Note

Pagina 140

Section 17 -Output Device Programming17–3If a relay is energized before a 4-wire smoke detector is reset, the relay will be stopped by theinterruption

Pagina 141

SL150 Installation and Setup Guide17–402 Start: Zn TypNot Used 00If a zone type or system operation will be used to START the deviceaction, enter the

Pagina 142

Section 17 -Output Device Programming17–5arming status of the system.To program this, do the following:1. In ✱80 Interactive mode, choose Output Devic

Pagina 143 - DOC LOAD NO.: 3

SL150 Installation and Setup Guide17–6

Pagina 144 - Suite 200

18–1SECTION 18Zone Lists(✱✱81 Menu Mode)••••••••••••••••••••••••••••••••••••••••••••••••••In This Section♦About Zone List Menu Mode♦Zone List Displays

Commenti su questo manuale

Nessun commento