Security Link SL150 Guida alla Risoluzione dei Problemi Pagina 100

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 99
SL150 Installation and Setup Guide
18–2
Pager 1 Reporting - Zone List 06
Pager 1 reporting is an option that must be set up using zone list 06, and entering the
appropriate zones that will report to Pager 1, independent of the report code enabled.
The chosen zone numbers are to be entered into zone list 06 via field
81. If any of the zones
in zone list 06 faults in the armed state, the system will send an alarm report to Pager 1.
Pager 2 Reporting - Zone List 07
Pager 2 reporting is an option that must be set up using zone list 07, and entering the
appropriate zones that will report to Pager 2, independent of the report code enabled.
The chosen zone numbers are to be entered into zone list 07 via field
81. If any of the zones
in zone list 07 faults in the armed state, the system will send an alarm report to Pager 2.