MASTER/SLAVE CONNECTION
Use a two wire shielded cable and run it through a UL listed conduit for master/slave connection.
Follow the wiring diagram as shown below.
Master Board Slave Board
+.....................Positive to Positive...................+
-...................Negative to Negative...................-
Before connecting master/slave gate operators together, test and adjust the limit switches and the ERDs
for each operator as “stand alone” machines. All accessories must be installed on the master board, no
exception.
See page 22 for dip switch settings.
Connect shield to
slave metal frame
only.
Use UL listed
conduit
Shielded
cable